Highlights 

Single phased back-up power supplies of EM series

   
 
 
OFF LINE Back-up Power Supplies
 
Characteristics of OFF LINE UPS are equal to the LINE INTERACTIVE type with the exception of the input voltage range (it does not have its own AVR circuit).

 


Type Power Back-up time
Dimensions Weight
UPS [VA] [W] [min]** W x H x D [mm] [kg]
EM 200P* 200 120 80 172 x 180 x 390 14,0
EM 600* 600 360 15 172 x 180 x 390 17,6
EM 800* 800 480 10 172 x 180 x 390 20,0
 
Legend:
A - Uninterruptible Power Supply with the voltage stabilization
P - prolonged back-up time
T - Uninterruptible Power Supply of 600 VA in the 172 x 360 x 460 mm cabinet
R - Uninterruptible Power Supply designed to be built-in the 19" rack
* - a possibility of putting the UPS into operation without the presence of the input mains and a possibility of switching off the acoustic signalling of an input mains failure.
** - at computer load



LINE INTERACTIVE Back-up Power Supplies
 
LINE INTERACTIVE supplies of EM series are suitable for uninterruptible power supply of PC-type computers, computer cash registers, cash registers based on the PC with a fiscal module, electronic cash registers, telephone centres and faxes against electric current failures in places, where there is a high voltage fluctuation in the public mains. They are automatically switched over into the back-up mode in case of a current failure, then in case of an input voltage that is off the input voltage range (150 up to 268 V).

LINE INTERACTIVE UPS are noted for operation at a large input voltage range in the presence of the input mains, while they do not change over into the back-up mode. It is enabled by the built-in AVR circuit (Automatic Voltage Regulation). The output voltage stabilisation in the mains mode runs without changing over into the back-up mode, whereby the battery life-span is prolonged. The intelligent charger guarantees quick and optimal battery charging. The battery is charged also when the switch is in the off position. The UPS is equipped with an electronic fuse that protects the UPS against overload in the mains and back-up mode. A typical switch-over time into the back-up mode is 6 ms.
 

Type Power output
Back-up time
Dimensions Weight
UPS [VA] [W] [min]** W x H x D [mm] [kg]
EM 200AP* 200 120 80 72 x 180 x 390 20,01
EM 600AP* 600 360 30 172 x 180 x 390 20,0
EM 600AT*° 600 360 65 172 x 360 x 460 34,0
EM 600ATP*° 600 360 90 172 x 360 x 460 42,0
EM 600A* 600 360 15 172 x 180 x 390 17,6
EM 800A* 800 480 10 172 x 180 x 390 20,0
EM 1200A*° 1200 720 25 172 x 360 x 460 38,0
EM 1200AP*° 1200 720 40 172 x 360 x 460 46,0

Note:

* - a possibility of putting the UPS into operation without the presence of the input mains and a possibility of switching off the acoustic signalling of an input mains failure
° - contain the communication module UK 80 (RS 232)
** - at computer load


Type Power Back-up time Dimensions Weight
UPS [VA] [W] [min]* W x H x D [mm] [kg]
EM 600AR 600 360 15 483 x 88 x 350 16,0
EM 800AR 800 480 10 483 x 88 x 350 16,0
EM 800ARS 800 480 40 483 x 176 x 440 38,0
EM 1200ARS 1200 720 25 483 x 176 x 440 38,0

 

Note:
* - at computer load

Foregoing types of equipment have a possibility of putting the UPS into operation without the presence of the input mains and a possibility of switching off the signalling of an input mains failure. All contain the communication module UK 80 (RS 232).
pinWe supply all over the world