Highlights
DC/AC Inverters
Inverters convert input DC voltage into output AC voltage of 115/230 V, 50/60 Hz (according to type of inverter). Inverters according to the type are designed for power supply of electronic systems, information and regulation technology devices and other systems. All types of inverters have input and output galvanic isolation.
Self operating inverters
Inverters of SH series (self operating with single phased sine output and optional external by-pass)
Type | U in [VDC] |
U out [VAC] |
Output | Power [VA] |
Power [W] |
Dimensions W x H x D [mm] |
Weight [kg] |
SH 108 | 220 | 230 | sinus | 1200 | 1060 | 170 x 220 x 460 | 10 |
SH 108RS | 220 | 230 | sinus | 1200 | 1060 | 483(435)* x 4U x 450 | 17 |
Note:
Inverters marked with „RS“ are designed for 19“ rack.
* - First value specifies front panel width second value specifies width of rack.
* - First value specifies front panel width second value specifies width of rack.
Electronic switches RP (for single phased inverters with sinus output)
By-pass type |
Max. switch | Max. switch time |
Dimensions W x H x D [mm] |
Weight [kg] |
||
Power [kVA] |
Current [A] |
inv./mains | mains/inv. | |||
RP 215 | 1,5 | 8 | 6 | 6 | 170 x 60 x 300 | 1,8 |
RP 230 | 3,2 | 16 | 6 | 6 | 170 x 60 x 300 | 2,0 |
RP 215 or RP 230 switch can be added to all types of inverters with single-phased sine output (see table with types of switches). RP switch is universal, intelligent By-pass, which is able to monitor two input mains with sinus wave shape and to switch the load automatically between the mains.
Inverters SLI series (self operating inverters without bypass)
Type | U in [VDC] |
U out [VAC] |
Power [VA] |
Power [W] |
Dimensions W x H x D [mm] |
Weight [kg] |
24 V
|
||||||
SLI 15-24-230 | 20-36 | 200-240 | 1800 | 1500 | 483 x 45(1U) x 422 | 5,6 |
48 V
|
||||||
SLI 15-48-230 | 40-72 | 200-240 | 1800 | 1500 | 483 x 45(1U) x 422 | 5,6 |
Inverters SLI series (self operating inverters with by-pass)
Type | U in [VDC] |
U out [VAC] |
Power [VA] |
Power [W] |
Dimensions W x H x D [mm] |
Weight [kg] |
24 V
|
||||||
SLI 15-24-230-STS | 20-36 | 200-240 | 1800 | 1500 | 483 x 45(1U) x 422 | 5,6 |
48/60 V
|
||||||
SLI 15-48-230-STS | 40-72 | 200-240 | 1800 | 1500 | 483 x 45(1U) x 422 | 5,6 |
Inverters in parallel cooperation
Inverters SLI series (max. 6 pcs of parallel connected inverters with by-pass)
Typ | U in [VDC] |
U out [VAC] |
Power [VA] |
Power [W] |
Dimensions W x H x D [mm] |
Weight [kg] |
24 V
|
||||||
SLI 15-24-230-STS-P3* | 20-36 | 200-240 | 1800 | 1500 | 483 x 45(1U) x 422 | 5,6 |
48/60 V
|
||||||
SLI 15-48-230-STS-P3* | 40-72 | 200-240 | 1800 | 1500 | 483 x 45(1U) x 422 | 5,6 |
Inverters RDI series (max. 16 pcs of parallel connected inverters with optional external by-pass)
Typ | U in [VDC] |
U out [VAC] |
Power [VA] |
Power [W] |
Dimensions W x H x D [mm] |
Weight [kg] |
220 V
|
||||||
RDI 3000VA-220VDC-230VAC | 180-260 | 200-240 | 3000 | 3000 | 438 x 89(2U) x 348 | 15 |
Electronic switches STM for inverters of RDI series with single phase output
By-passu type |
Max. switch | Max. switch time |
Dimensions W x H x D [mm] |
Weight [kg] |
||
Power [kVA] |
prúd [A] |
inv./mains | mains/inv. | |||
STM 65-RDI-230V | 15,0 | 65 | 5 | 5 | 438 x 135 x 316 | 7,5 |
STM 150-RDI-230V | 34,5 | 150 | 5 | 5 | 438 x 135 x 348 | 9 |
Possible to add STM 65-RDI or STM 150-RDI switch to all types of RDI inverters with single phase output (see table types of switches).
Control and accessories of RDI inverters
Type | Description |
SYS3000 monitoring unit | Monitoring unit of RDI and Arcon RDI inverters |
SYS100 PCB Alarm | relay contacts for alarms of RDI and Arcon RDI inverters without by-pass |
Bus Interface 16 invertor | DPS for connection of up to 16 pcs of RDI and Arcon RDI inverters |
Kit RDI | input and output cables for RDI |
There is also possible to add local controlling and monitoring panel SYS 3000 to RDI inverters. Remote monitoring by PC of such a system is possible.
Inverters TSI series (parallel connected inverters without el. by-pass - up to 32 pcs )
Type | U in [VDC] |
U out [VAC] |
Power [VA] |
Power [W] |
Dimensions W x H x D [mm] |
Weight [kg] |
48 V
|
||||||
TSI-REG-48Vdc-230Vac-Module VEDA | 40-60 | 200-240 | 500 | 400 | 142 x 45(1U) x 264 | 2,0 |
TSI-REG-48Vdc-230Vac-Module BRAVO | 40-60 | 200-240 | 2500 | 2000 | 102 x 89(2U) x 435 | 5,0 |
Inverters TSI series (parallel connected inverters with el. by-pass - up to 32 pcs )
Type | U in [VDC] |
U in [VAC] |
U out [VAC] |
Power [VA] |
Power [W] |
Dimensions W x H x D [mm] |
Weight [kg] |
48 V
|
|||||||
TSI-EPC-48Vdc-230Vac-Module NOVA | 40-60 | 150-264 | 200-240 | 750 | 525 | 106 x 45(1U) x 325 | 2,1 |
TSI-EPC-48Vdc-230Vac-Module MEDIA | 40-58 | 185-265 | 200-240 | 1500 | 1200 | 102 x 88(2U) x 380 | 2,4 |
TSI-BRAVO-EPC-24Vdc-230Vac-Module | 19-32 | 185-300 | 200-240 | 1500 | 1200 | 102 x 88(2U) x 435 | 5,0 |
TSI-BRAVO-EPC-48Vdc-230Vac-Module | 40-60 | 185-265 | 200-240 | 2500 | 2000 | 102 x 88(2U) x 435 | 5,0 |
TSI-BRAVO-EPC-60Vdc-230Vac-Module | 48-72 | 185-265 | 200-240 | 2500 | 2000 | 102 x 88(2U) x 435 | 5,0 |
TSI-BRAVO-EPC-110Vdc-230Vac-Module | 90-160 | 185-265 | 200-240 | 2500 | 2000 | 102 x 88(2U) x 380 | 5,0 |
TSI-BRAVO-EPC-220Vdc-230Vac-Module | 170-270 | 185-265 | 200-240 | 2500 | 2000 | 102 x 88(2U) x 435 | 5,0 |