header picture
Company           Products           Services           Contact           Cooperation           Cogeneration

PRODUCTS


Power supplies

Other

Software support



DC/AC Inverters

Inverters convert input DC voltage into output AC voltage of 115/230 V, 50/60 Hz (according to type of inverter). Inverters according to the type are designed for power supply of electronic systems, information and regulation technology devices and other systems. All types of inverters have input and output galvanic isolation.

Self operating inverters
Inverters of S series (self operating with trapezial output)
Type UIN
[VDC]
UOUT
[VAC]
Output Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
S 032A 24 230 trapezial 300 300 172 x 184 x 353 11
S 032R 24 230 trapezial 300 300 483 x 133 x 350 12
S 034A 48 230 trapezial 300 300 172 x 184 x 353 11
S 034R 48 230 trapezial 300 300 483 x 133 x 350 12
S 036A 60 230 trapezial 300 300 172 x 184 x 353 11
S 036R 60 230 trapezial 300 300 483 x 133 x 350 12

Inverters of SH series (self operating with single phased sine output and optional external by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Output Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
SH 108 220 230 sinus 1200 1060 170 x 220 x 460 10
SH 108RS 220 230 sinus 1200 1060 483(435)* x 4U x 450 17

Note:
Inverters marked with „RS“ are designed for 19“ rack.
* - First value specifies front panel width second value specifies width of rack.

Electronic switches RP (for single phased inverters with sinus output)
By-pass
type
Max. switch Max. switch time Dimensions
W x H x D
[mm]
Weight
[kg]
power
[kVA]
current
[A]
inv./mains mains/inv.
RP 215 1,5 8 6 6 170 x 60 x 300 1,8
RP 230 3,2 16 6 6 170 x 60 x 300 2,0

RP 215 or RP 230 switch can be added to all types of inverters with single-phased sine output (see table with types of switches). RP switch is universal, intelligent By-pass, which is able to monitor two input mains with sinus wave shape and to switch the load automatically between the mains.

Inverters SLI series (self operating inverters without bypass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
SLI 7-24-230 20-36 200-240 750 700 483 x 45(1U) x 422 4,6
SLI 15-24-230 20-36 200-240 1800 1500 483 x 45(1U) x 422 5,6
48 V
SLI 7-48-230 40-72 200-240 750 700 483 x 45(1U) x 422 4,6
SLI 15-48-230 40-72 200-240 1800 1500 483 x 45(1U) x 422 5,6

Inverters SLI series (self operating inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
SLI 15-24-230-STS 20-36 200-240 1800 1500 483 x 45(1U) x 422 5,6
48/60 V
SLI 15-48-230-STS 40-72 200-240 1800 1500 483 x 45(1U) x 422 5,6

Inverters STI series (self operating inverters without by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48/60 V
STI 300VA 40-72 200-240 300 300 483 x 45(1U) x 348 5
STI 600VA 40-80 200-240 600 600 483 x 89(2U) x 348 8
STI 1000VA 40-80 200-240 1000 1000 438 x 89(2U) x 348 8

Inverters ARCON ST series (self operating inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
ARCON ST 1250VA 19-35 200-240 1250 1250 450 x 89(2U) x 510 11
ARCON ST 3000VA 19-35 200-240 3000 3000 450 x 89(2U) x 510 17
48/60 V
ARCON ST 300VA 40-72 200-240 300 300 450 x 89(2U) x 510 8
ARCON ST 600VA 40-80 200-240 600 600 450 x 89(2U) x 510 10
ARCON ST 1250VA 40-80 200-240 1250 1250 450 x 89(2U) x 510 11
ARCON ST 3000VA 40-80 200-240 3000 3000 450 x 89(2U) x 510 17
110 V
ARCON ST 1250VA 90-160 200-240 1250 1250 450 x 89(2U) x 510 11
ARCON ST 3000VA 90-160 200-240 3000 3000 450 x 89(2U) x 510 17
220 V
ARCON ST 3000VA 180-260 200-240 3000 3000 450 x 89(2U) x 510 17

Inverters PHASYS series (self operating inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48 V
PHASYS SA 1500VA 40-58 220/230 1500 1050 483 x 133(3U) x 460 16,5
PHASYS SA 3000VA 40-58 220/230 3000 2100 483 x 133(3U) x 460 19,5
PHASYS SA 4500VA 40-58 220/230 4500 3150 438 x 133(3U) x 460 21,5

Inverters in parallel cooperation
Inverters SLI series (max. 6 pcs of parallel connected inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
SLI 15-24-230-STS-P3* 20-36 200-240 1800 1500 483 x 45(1U) x 422 5,6
48/60 V
SLI 15-48-230-STS-P3* 40-72 200-240 1800 1500 483 x 45(1U) x 422 5,6

Note:
* - STS only at request of auxiliary mains connection
* - P3 only when three phased system is needed, possible to use max. 18 pcs of parallel connected modules
(3 x 6 for each phase)

Inverters RDI series (max. 16 pcs of parallel connected inverters with optional external by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
RDI 1250VA 19-35 200-240 1250 1250 438 x 89(2U) x 348 8,5
RDI 3000VA 19-35 200-240 3000 2200 438 x 89(2U) x 348 15
48/60 V
RDI 1000VA 40-80 200-240 1000 1000 438 x 89(2U) x 348 8,5
RDI 3000VA 40-80 200-240 3000 3000 438 x 89(2U) x 348 15
110 V
RDI 3000VA 90-150 200-240 3000 3000 438 x 89(2U) x 348 15
220 V
RDI 3000VA 180-260 200-240 3000 3000 438 x 89(2U) x 348 15

Inverters ARCON RDI series (max. 16 pcs of parallel connected inverters with optional external by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48/60 V
Arcon RDI 4000VA 40-80 200-240 4000 3500 438 x 89(2U) x 440 18

Electronic switches STM (for inverters of RDI and ARCON RDI series with single phase output)
By-pass
type
Max. switching Max. switch time Dimensions
W x H x D
[mm]
Weight
[kg]
power
[kVA]
current
[A]
inv./mains mains/inv.
STM 65-RDI 15,0 65 5 5 438 x 135 x 316 7,5
STM 150-RDI 34,5 150 5 5 438 x 135 x 348 9

Possible to add STM 65-RDI or STM 150-RDI switch to all types of RDI and ARCON RDI inverters with single phase output (see table types of switches).

RControl and accessories of RDI & Arcon RDI inverters
Type Description
SYS3000 monitoring unit monitoring unit of RDI and Arcon RDI inverters
SYS100 PCB Alarm relay contacts for alarms of RDI and Arcon RDI inverters without by-pass
Bus Interface 16 invertor DPS for connection of up to 16 pcs of RDI and Arcon RDI inverters

There is also possible to add local controlling and monitoring panel SYS 3000 to RDI and ARCON RDI inverters. Remote monitoring by PC of such a system is possible.

Inverters TSI series (up to 32 pcs of parallel connected inverters without by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48 V
TSI Veda Reg 500VA 40-60 200-240 500 400 142 x 45(1U) x 264 2,0
TSI BravoReg 2500VA 40-60 200-240 2500 2000 102 x 89(2U) x 435 5,0

Inverters TSI series (up to 32 pcs of parallel connected inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48 V
TSI Nova Epc 750VA 40-60 200-240 750 525 106 x 45(1U) x 325 2,1
TSI Bravo Epc 2500VA 40-60 200-240 2500 2000 102 x 89(2U) x 435 5,0

Inverters PHASYS series (up to 6 pcs of parallel connected inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48 V
PHASYS 1500VA 40-58 200/230 1500 1050 483 x 133(3U) x 460 16,5
PHASYS 3000VA 40-58 200/230 3000 2100 483 x 133(3U) x 460 19,5
PHASYS 4500VA 40-58 200/230 4500 3150 483 x 133(3U) x 460 21,5




Homepage