header picture
Home page           Company           Products           Services           Contact           Cooperation           Cogeneration

PRODUCTS


Power supplies

Other

Software support



DC/AC Inverters

Inverters convert input DC voltage into output AC voltage of 115/230 V, 50/60 Hz (according to type of inverter). Inverters according to the type are designed for power supply of electronic systems, information and regulation technology devices and other systems. All types of inverters have input and output galvanic isolation.

Self operating inverters

Inverters of SH series (self operating with single phased sine output and optional external by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Output Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
SH 108 220 230 sinus 1200 1060 170 x 220 x 460 10
SH 108RS 220 230 sinus 1200 1060 483(435)* x 4U x 450 17

Note:
Inverters marked with „RS“ are designed for 19“ rack.
* - First value specifies front panel width second value specifies width of rack.

Inverters SLI series (self operating inverters without bypass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
SLI 15-24-230 20-36 200-240 1800 1500 483 x 45(1U) x 422 5,6
48 V
SLI 15-48-230 40-72 200-240 1800 1500 483 x 45(1U) x 422 5,6

Inverters SLI series (self operating inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
SLI 15-24-230-STS 20-36 200-240 1800 1500 483 x 45(1U) x 422 5,6
48/60 V
SLI 15-48-230-STS 40-72 200-240 1800 1500 483 x 45(1U) x 422 5,6


Inverters in parallel cooperation
Inverters SLI series (max. 6 pcs of parallel connected inverters with by-pass)
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
24 V
SLI 15-24-230-STS-P3* 20-36 200-240 1800 1500 483 x 45(1U) x 422 5,6
48/60 V
SLI 15-48-230-STS-P3* 40-72 200-240 1800 1500 483 x 45(1U) x 422 5,6

Note:
* - STS only at request of auxiliary mains connection
* - P3 only when three phased system is needed, possible to use max. 18 pcs of parallel connected modules
(3 x 6 for each phase)


Inverters TSI series (parallel connected inverters without el. by-pass - up to 32 pcs )
Type UIN
[VDC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48 V
TSI-REG-48Vdc-230Vac-Module VEDA 40-60 200-240 500 400 142 x 45(1U) x 264 2,0
TSI-REG-48Vdc-230Vac-Module BRAVO 40-60 200-240 2500 2000 102 x 89(2U) x 435 5,0

Inverters TSI series (parallel connected inverters with el. by-pass - up to 32 pcs )
Type UIN
[VDC]
UIN
[VAC]
UOUT
[VAC]
Power
[VA]
Power
[W]
Dimensions
W x H x D
[mm]
Weight
[kg]
48 V
TSI-EPC-48Vdc-230Vac-Module NOVA 40-60 150-264 200-240 750 525 106 x 45(1U) x 325 2,1
TSI-EPC-48Vdc-230Vac-Module MEDIA 40-58 185-265 200-240 1500 1200 102 x 88(2U) x 380 2,4
TSI-BRAVO-EPC-24Vdc-230Vac-Module 19-32 185-300 200-240 1500 1200 102 x 88(2U) x 435 5,0
TSI-BRAVO-EPC-48Vdc-230Vac-Module 40-60 185-265 200-240 2500 2000 102 x 88(2U) x 435 5,0
TSI-BRAVO-EPC-60Vdc-230Vac-Module 48-72 185-265 200-240 2500 2000 102 x 88(2U) x 435 5,0
TSI-BRAVO-EPC-110Vdc-230Vac-Module 90-160 185-265 200-240 2500 2000 102 x 88(2U) x 380 5,0
TSI-BRAVO-EPC-220Vdc-230Vac-Module 170-270 185-265 200-240 2500 2000 102 x 88(2U) x 435 5,0



Homepage
© Elteco 2014