Tester of batteries BT 100 - 400


Tester of batteries is assigned for execution of prophylactic capacity tests of batteries by discharging. It is possible to test any type of batterys by the tester.


Base characteristics of device
  • Control unit with LCD display controlled with microprocessor
  • Monitoring up to 128 battery cells
  • Programmable process of discharge
  • Fully programmable process of measurement at discharge with the autonomous operation without PC
  • Possibility of upgrade of firmware - completing new characteristics
  • Galvanic isolated user`s interface


  • Monitoring
  • Monitoring of various cells - 2, 4, 6, 8, 10 and 12 V
  • Max. 128 cells with voltage 2, 4, 6 V or 64 cells with voltage 8, 10, 12 V
  • Voltage of the monitored battery set
  • Voltage of single battery cells
  • Balance of voltage of the single cells of battery set
  • Check up of the discharge current of battery during back-up
  • Monitoring of the ambient temperature of battery
  • Completion of the battery discharge according to time, battery voltage, number of cells with min. voltage, ...
  • Display of capacity of the battery after the completion of discharge of the battery
  • Record of the operational reports in memory
  • Setting of an interval of measurement of cells voltage within 1 - 600 min.
  • Storage of the discharging characteristics directly in the device
  • Consecutive display of all measured and configured data on LCD display
  • Other features


  • Basic parameters
    Input
    voltage of tested battery 10 - 400 V DC
    discharging current 10 ÷ 260 V DC - 5 ÷ 100 A
    260 ÷ 400 V DC - 5 ÷ 50 A
    input protection internal fuse 125 A
    powering 90 ÷ 264 V AC - 40 ÷ 280 V DC
    Output
    connection to load 2 x 14 kW
    max. range of voltage to load 0 ÷ 400 V DC
    max. current to load 2 x 40 A
    protection of the output of module BT electronically 100 A
    • protection of battery against the deep discharge battery disconnecter
    shunt for measuring of the battery current 0 ÷ 150 A
    Dimensions W x D x H
    Module BT 100-400 300 x 540 x 570 mm
    Load BTZ 14kVA 300 x 480 x 710 mm



    Note: